Compatibility: XMS 2.0+ Expects: AH 0eH DX XMS handle (as obtained via XMS 09H) ────────────────────────────────────────────────────────────────── Returns: AX status: 0000H = successful 0001H = error BH current lock count BL current number of free XMS handles DX size of the block, in K-bytes ────────────────────────────────────────────────────────────────── Info: This fn obtains information about an extended memory block. To get the 32-bit address of the block, use XMS 0cH (lock XMB). See Also: XMS Functions Extended Memory Specification (XMS) DOS Functions -♦-